XC600 High Performance Vector VFD
Product advantages
Dynamic Braking
Supports dynamic braking and DC injection braking for rapid equipment stopping.
Automatic Optimization
Automatically optimizes the V/F curve based on the load, with automatic voltage regulation (AVR).
Flexible Production
Supports up to 15 speed control levels with independent settings for acceleration and deceleration times.
High-Response Torque Control
Under PG vector control, torque is accurately controlled within ±5%.
Extensive I/O Expansion
Supports up to 8 digital inputs and 2 analog inputs to meet complex control needs.
Industrial Environment Adaptability
IP20 protection rating, forced air cooling.



Application
Industrial Automation and Heavy-Duty Equipment
Provides precise speed control, reduces mechanical shock, and extends equipment life.
Pumps, Fans, and HVAC Systems
Automatically adjusts motor speed based on load, optimizing energy efficiency and reducing energy consumption.
Paper and Textile Industries
High-precision speed and torque control reduces quality fluctuations and improves production efficiency.
Mining, Metallurgy, and Pharmaceutical Industries
Provides high starting torque and precise control to improve production consistency.
Product specification
|
Project |
Item Description |
||
|
Import |
Rated voltage and frequency |
Single-phase 220 V: single-phase 220V, 50 Hz / 60 Hz; three-phase 380 V: three-phase 380V, 50Hz / 60Hz; Three-phase 690 v level: three-phase 690V, 50Hz / 60Hz. |
|
|
Allowable voltage fluctuation range |
Single-phase 220 V: 220~260V; three-phase 380 V: 320~460V; Three-phase 690-volt stage: 586~760V. |
||
|
Output |
voltage |
0~690V |
|
|
frequency |
0-600Hz |
||
|
overload capacity |
Type G: 150% rated current for 1 min: Type P: 120% rated current for 1 minute. |
||
|
Control Performance |
control method |
No PG vector control, no PG vector control, no open-loop V / F control, no PG torque control, no PG torque control |
|
|
Speed control accuracy |
± 0.5% rated Synchronized speed (with no PG vector control); ± 0.1% rated Synchronized speed (with PG vector control): ± 1% rated Synchronized speed (V / F control): |
||
|
Speed range |
1:2000 (with PG vector control) 1:100 (no PG vector control) 1:50 (V / F control) |
||
|
starting torque |
1.0 Hz: 150% rated torque (V / F control); 0.5 Hz: 150% Rated torque (without PG vector control): OHz: 180% rated torque (with PG vector control): |
||
|
velocity perturbation |
± 0.3% rated synchronous speed (without PG vector control): ± 0.1% rated synchronous speed (with PG vector control); |
||
|
Torque control accuracy |
± 10% rated torque (no PG vector control, no PG torque control); ± 5% rated torque (with PG vector control, with PG torque control). |
||
|
Torque response |
20 ms (no PG vector control) 10 ms (with PG vector control) |
||
|
Frequency accuracy |
Number setting: highest frequency ± 0.01%; simulation setting: highest frequency ± 0.5% |
||
|
frequency resolution |
Simulation setting |
And 0.1% of the highest frequency |
|
|
Digital setting accuracy |
0.01Hz |
||
|
External pulse |
And 0.1% of the highest frequency |
||
|
Recurrent ascension |
Automatic torque lift; manual torque lift is 0.1~12.0% |
||
|
V / F curve (voltage and frequency characteristic) |
The rated frequency is set at 5~650 Hz, including constant torque, decreasing torque 1, decreasing torque 2, decreasing torque 3, and custom V / F |
||
|
Add deceleration curve |
Two ways: linear acceleration and deceleration and S curve acceleration and deceleration; 15 kinds of acceleration and deceleration time, time unit (0.01s,0.1s, 1s) optional, the longest 1000 minutes |
||
|
braking |
dynamic braking |
EN600 series 380V 15KW and below have built-in braking units, only in (+) and PB Between brake resistance: 18.5 KW and above power section can be optional internal brake unit, only between (+) and PB, can also be connected between (+) and (-): 690V full series only supports the external brake unit. The EN500 series can connect the external brake unit between (+) and (-). |
|
|
DC injection braking |
Start and stop actions are optional respectively, with action frequency 0~15Hz, action current 0~100% rated current, and action time 0~30.0s |
||
|
crawl |
Point action frequency range: OHz ~ upper limit frequency; point action acceleration and deceleration time is 0.1~6000.0 seconds |
||
|
Multi-section speed operation |
Through the built-in PLC or control terminal to achieve multi-segment speed operation, up to 15 segments, each segment corresponding to a separate acceleration and deceleration time, the built-in PLC support power storage |
||
|
Built-in PID controller |
Can easily constitute a closed-loop control system |
||
|
Project |
Item Description |
|
|
Control Performance |
Automatic energy saving operation |
According to the load situation, the V / F curve is automatically optimized to realize the energy-saving operation |
|
Automatic Voltage Adjustment (AVR) |
When the power grid voltage changes, it can automatically keep the output voltage constant |
|
|
Automatic flow limit |
Automatic limit the current during operation to prevent frequent overcurrent fault trip |
|
|
Carrier modulation |
The carrier adjust carrier adjusted according to the load characteristics |
|
|
The rotational speed tracking starts again |
Realize the non-impact smooth start of the rotating motor |
|
|
Run the Function |
Run the command given to the channel |
Operation keyboard given, control terminal given, communication given, can be switched through a variety of ways |
|
Run the frequency given the channel |
Main auxiliary given, to achieve a main adjustment, a fine-tuning control. Digital given, analog given, pulse given, pulse width given, communication given can be switched at any time in many ways |
|
|
Bundle function |
The running command channel and the frequency given channel can be arbitrarily bundled, synchronous switching |
|
|
Input Output Features |
Digital input channel |
8 universal digital input channel, the maximum frequency is 1 KHz, of which 1 can be used as a pulse input channel, the maximum input is 50 KHz, can be expanded to 14 channels |
|
analog input channel |
2 channels of analog input channel, where AI1 can choose 4 ~ 20 mA or 0~10V output, AI2 channel is differential input, 4 ~ ~ 20 mA or-10~10V input is optional, can be extended to 4 channels of analog input |
|
|
Pulse output channel |
The pulse square wave signal output of 0.1 ~ 20 KHz can realize the output of physical quantities such as set frequency and output frequency |
|
|
analog output channel |
2 analog signal output, where A01 channel is optional 4 ~ 20 mA or 0~10V, A02 channel is optional 4 ~ 20 mA or 0~10V can realize the output of physical quantity such as set frequency and output frequency, which can be extended to 4 analog output |
|
|
Featured Function |
Fast flow limit |
Limit limit frequency converter flow, more reliable operation |
|
Single pulse control |
Suitable for the need to one key control the frequency converter up, stop, press, and then press stop, and then press again, so repeated. This use is simple and reliable, and it is not easy to misoperate |
|
|
Long control |
Fixed length control can be achieved |
|
|
timing control |
Timing control function: set the time range of 0.1Min~6500.0Min |
|
|
Virtual terminal |
Five sets of virtual input, output 10, which can achieve simple logic control |
|
|
Function Keyboard |
The keyboard display |
Set frequency, output frequency, output voltage, output current and other parameters can be displayed |
|
Key lock |
Lock in some or all of the keys |
|
|
defencive function |
Short circuit detection, input and output phase deficiency protection, overcurrent protection, overvoltage protection, overvoltage protection, undervoltage protection, overheating protection, overload protection, underprotection, relay suction protection, terminal protection, power failure non-stop protection, etc |
|
|
Environment |
Where to use |
Indoor, not directly exposed to sunlight, no dust, corrosive gas, combustible gas, oil mist, water steam, dripping water or salt, etc |
|
height |
Below the 1,000 m.(Above 1000 m, the output current per 1000 m decreases the rated current) |
|
|
ambient temperature |
-10℃ ~ + 40℃ (ambient temperature is 40℃ ~50℃, please reduce or enhance heat dissipation) |
|
|
The surrounding humidity |
Less than 95% RH, and the anhydrous beads were condensed |
|
|
vibrate |
Less than 5.9 m / sec (0.6g) |
|
|
Storage temperature |
-40℃~+70℃ |
|
|
Structure |
levels of protection |
IP20 |
|
cooling-down method |
air blast cooling |
|
|
Way to install |
Wall hanging type and cabinet type |
|
EN750 High Performance Vector VFD



Product specification
|
Input |
rated volt.,frequency |
1 phase220V,50hz/60hz;3 phase380V,50hz/60hz |
|
|
Allowedvolt.range |
1phase 220v:220-260V;3Phase380V320-460V |
||
|
Output |
Voltage |
0~input voltage |
|
|
Frequency |
0~600Hz |
||
|
Over loading capacity |
150%of rated current for 1 minute. |
||
|
Control performance |
Control mode |
1.Without PG vector control(supportsynchronous motor and Asynchronous motors) 2.PG Vector control(support synchronous motor and Asynchronous motors) 3.V/F control 4.Torque control(support synchronous motor and Asynchronous motors) 5.PG torque control(support synchronous motor and Asynchronous motors) 6.Position control(support synchronous motor and Asynchronous motors) |
|
|
Velocity control precision |
±0.5%rated Synchronous speed(without PG vector control) ±0.1%rated Snchronousspeed(with PG vector control) ±1%rated Snchronous speed(V/f control) |
||
|
Speed regulation range |
1:2000(with PG vector control)1:200(without PG vector control)1:50(V/fcontrol) |
||
|
Start uptorque |
1.0Hz:150%rated torque(V/f control) 0.5Hz:150%rated torque(without PG vector control) 0Hz:180%rated torque(with PG vector control) |
||
|
Speed fluctuation |
±0.3%rated Synchronous speed(without PG vector control) ±0.1%rated Snchronous speed(with PG vector control) |
||
|
Torque control accuracy |
±8%rated torque(without PG vector control,without torque control) ±5%rated torque(with PG vector control,with torque control) |
||
|
Torque response |
≤20ms(without PGvector control); ≤10ms(with PG vector control) |
||
|
Frequency precision |
Digital setting:max.frequency x±0.01%; Analog setting:max frequency x±0.5% |
||
|
Freq resolution |
Simulation settings | 0.1%of max.frequency | |
| Digital setting accuracy | 0.01Hz | ||
| external pulse | 0.1%of the max.frequency | ||
| Torque boost | Automatic torque boost;The manual torque is increased by 0.1~30.0%. | ||
|
V/F curve(volt. frequency characteristics) |
Setting rated frequency at the range of 5~650Hz,by choosing constant torque, degressive torque 1,degressive torque 2,degressive torque 3,self-defined V/F, VF total6 kinds of curve. | ||
| Acceleration Deceleration curve | Two modes:straight line acceleration and deceleration;S curve acceleration and deceleration;15 kindsof acceleration and deceleration time,time unit (0.01s,0.1s,1s)for option,max.Time For 1000 minutes. | ||
| Brake |
Power consumption brake |
3 phase22kw below power range has built-in brake unit,only need to add brake resistance between(+)and PB;Built-in braking unitis optional for power range of 30KW or above,only dd brake resistance between(+)and PB,or externally connect braking unit between(+)and(-). |
|
| DC brake | Start,stop action for option,action frequency 0~15Hz,action current 0~ 100%of rated current,action time 0~30.0s. | ||
| Jog | Jog frequency range:OHz~~up limit frequency;jog acceleration and deceleration time 0.1~6000.0 seconds for setting. | ||
| Multi-section speed run | Realized by inbuilt PLCor control terminal;with 15 section speed,each section speed with separately acceleration and deceleration time;with inbuilt PLC can achieve reserve when power down. | ||
|
Control performance |
Inbuilt PID controller | Convenient to makeclosed-loop control system | |
| Automatic voltage(AVR) | Automatically keep output voltage constant,when the powergrid voltage fluctuation | ||
| Automatic current limiting | Current limited automatically under run mode in avoid of inverter over- current frequently to trip. | ||
| Carrier modulation | Make rotating motor smoothly start without shocking | ||
| Speed tracking restart | Make rotating motor smoothly start without shocking | ||
| Running function | running command specified channel | Keypad specified,Control terminal specified,communication specified, can switch through various means. | |
| Running frequency specified channel | Main &auxiliary specified to a realize one main adjusting and one fine control.Digital specified,analog specified,pulse specified,pulse width specified,communication specified and others,which can be switched by many means at any time. | ||
| Binding function | Run command channel and frequency specified channel can bind together randomly and switch synchronously | ||
|
Input output characte ristic |
Digital input channel |
Channel5 for universal digital input,max.Frequency 1KHz,channel1 can be used as pulse input channel,max.Input 50KHz,Expansion terminals can be realized |
|
| Analog input channel | Channel2 foranalog input channel,AII is 0-10V input,AI2 can choose 4- 20mA or 0-10V or 0-20mA input,Expansion terminals can be realized | ||
| Pulse output channel | 0.1~20KHz pulse square signal output to achieve setting frequency,output frequency and other physical quantity output. | ||
| Analog output channel |
Channel 1 for analog output channel,AO can choose 0-20mA or 0-10V to achieve setting frequency,output frequency and other physical quantity output,which can be expanded to channel 4 analog output. |
||
|
Unique function |
Rapid current limit | Hardware-level current limiting circuitry,Limitinverter over current to the greatest point,and make it run more stably | |
| Monopulse control | Suitable for working site where need onebutton to controlinverter start and stop,first press to start,then press to stop,and that cycle repeats.Itsvery simple and reliable. | ||
| Fixed length control | Realize fixed length control | ||
| Timing control | Timing control function:setting time range 0.1Min~6500.0Min | ||
| Virtual terminal | Five groupvirtual input &output IO can realize simply logical control | ||
| Operating Keypad | Keypad display | The parameters as setting frequency,output frequency,output voltage, output current can be displayed | |
| Button Locked | Lock all or part ofthe buttons | ||
| Protection function | Motor power on Shot circuit test,input &output phase loss protection,over- current protection,over voltage protection,under voltage protection,over heat protection,overload protection,short-circuit protection to ground, terminal protection,terminal protection and no stop protection under power off.,etc. | ||
| Environment | Application site | Indoor,not bare to sunlight,no dust,no corrosive gas,no flammable gas,no vapor,no water drop or salt etc. | |
| Altitude | Under 1000 meter. (above 1000 meter requireto reduce volumeto use,output current reduce about 10%of rated currenvolt per 1000 meter high) | ||
| Environment temperature | -10℃~+40℃(environment temperature between 40℃~50℃,need to reduce volume or strengthen heat sink) | ||
| Environment humidity | Smaller than 95%RH,no dropcondenses | ||
| vibration | Smaller than 5.9M/S2(0.6g) | ||
| storage temperature | -40℃~+70℃ | ||
| Structure | Protection grade | IP20 | |
| Cooling mode | Forced air cooling and natural | ||
| Installation mode | Wall-mounted | ||
Hot Tags: high performance vector VFD, China high performance vector VFD manufacturers, suppliers, factory, Frameless Torque Motor, traffic counter sensor, low voltage vfd for large enterprises, Water Pump Inverter, Siemens Basic HMI, Low Voltage Servo DC Motor





